International Journal of Orthopaedics Sciences

A comparative study of distal tibia fracture treated with locking compression plate (LCP) versus expert tibia nail (ETN) - A prospective study

2020, Volume 6 Issue 1

A comparative study of distal tibia fracture treated with locking compression plate (LCP) versus expert tibia nail (ETN) - A prospective study

Author(s): Dr. SK Bhaskar, Dr. Sumit Kumar Pensia and Dr. BS Rao
Abstract: Material and Method: The study conducted from September 2017 to September 2019. 60 patient with distal tibia extrarticular close fracture AO type 43A were randomly selected which was admitted to trauma center JLN medical college ajmer. 30 of them were treated with locking compression plate and rest 30 with expert tibia nail. Patient were follow up for 12 month and evaluated by Olreud & Molander scoring system.
Pages: 128-133  |  1321 Views  151 Downloads
How to cite this article:
Dr. SK Bhaskar, Dr. Sumit Kumar Pensia, Dr. BS Rao. A comparative study of distal tibia fracture treated with locking compression plate (LCP) versus expert tibia nail (ETN) - A prospective study. Int J Orthop Sci 2020;6(1):128-133. DOI: 10.22271/ortho.2020.v6.i1c.1847
 